Short Description
China EBM PAPST AC Axial Fan Supplier Honest provides R2E220-AA40-B8 AC Axial Fans, 1-Phase, 50/60Hz, 230 VAC, 0.38/0.40A, 400VDB, uncoated, 220mm.
Phase | 1~ | 1~ | 1~ | |
Nominal voltage | VAC | 230 | 230 | 230 |
Frequency | Hz | 50 | 60 | 60 |
Type of data definition | fa | fa | fa | |
Valid for approval/ standard | CE | UL2111 | CE | |
Speed | min-1 | 2600 | 2600 | 2700 |
Power input | W | 85 | 95 | 90 |
Current draw | A | 0.38 | 0.40 | 0.40 |
Motor capacitor | µF | 3 | 2 | 2 |
Capacitor voltage | VDB | 400 | 400 | 400 |
Capacitor standard | P0 (CE) | UL | P0 (CE) | |
Min. back pressure | Pa | 0 | 0 | 0 |
Max. ambient temperature | ℃ | 55 | 55 | 55 |
Mass | 1.5kg |
Size | 220mm |
Surface of rotor | Uncoated |
Material of impeller | Plastic PA6, fiberglass-reinforced |
Number of blades | 11 |
Direction of rotation | Clockwise, seen on rotor |
Type of protection | IP44; depending on installation and position |
Insulation class | “F” |
Humidity | F1-2 |
Max. permissible ambient motor temp. (transp./ storage) | +80℃ |
Min. permissible ambient motor temp. (transp./ storage) | -40℃ |
Mounting position | Any |
Condensate discharge holes | None |
Operation mode | S1 |
Motor bearing | Ball bearing |
Leakage current | <0.75mA |
Motor protection | Thermal overload protector (TOP) wired internally |
Cable exit | Variable |
Protection class | I (if protective earth is connected by customer) |
Product conforming to standard | EN60335-1;CE |
approval | UL2111; CSA C22.2 Nr.77; CCC |