Short Description
China Rheodyne Stainless Steel Sample Loop Supplier Honest provides 7755-300 Stainless Steel Sample Loops, tolerance of the metal tubing bore.
Keywords: Sample Loop,
RHEODYNE STAINLESS STEEL LOOPS FOR MXT715-000 | ||||
Volume | Tubing | |||
7755-300 | 5 µL Sample Loop | 0.18 mm (0.007”) ID x 1/16” OD | ||
7755-301 | 10 µL Sample Loop | 0.30 mm (0.012”) ID x 1/16” OD | ||
7755-302 | 20 µL Sample Loop | 0.30 mm (0.012”) ID x 1/16” OD | ||
7755-303 | 50 µL Sample Loop | 0.51 mm (0.021”) ID x 1/16” OD | ||
7755-304 | 100 µL Sample Loop | 0.51 mm (0.021”) ID x 1/16” OD | ||
RHEODYNE STAINLESS STEEL LOOPS FOR 7125,7010 INJECTORS (DO NOT USE FOR 7725) |
||||
Volume | Tubing | |||
7020 | 5 µL Sample Loop | 0.18 mm (0.007”) ID x 1/16" OD | ||
7021 | 10 µL Sample Loop | 0.30 mm (0.012”) ID x 1/16" OD | ||
7022 | 20 µL Sample Loop | 0.51 mm (0.020”) ID x 1/16" OD | ||
7023 | 50 µL Sample Loop | 0.51 mm (0.020”) ID x 1/16" OD | ||
7024 | 100 µL Sample Loop | 0.51 mm (0.020”) ID x 1/16" OD | ||
7025 | 200 µL Sample Loop | 0.76 mm (0.030”) ID x 1/16" OD | ||
7026 | 500 µL Sample Loop | 0.76 mm (0.030”) ID x 1/16" OD | ||
7027 | 1.0 mL Sample Loop | 0.76 mm (0.030”) ID x 1/16" OD | ||
7028 | 2.0 mL Sample Loop | 1.0 mm (0.010”) ID x 1/16" OD | ||
7029 | 5.0 mL Sample Loop | 1.0 mm (0.040”) ID x 1/16" OD | ||
1876 | 10 mL Sample Loop | 2.0 mm (0.080”) ID x 1/8" OD | ||
1877 | 20 mL Sample Loop | 2.0 mm (0.080”) ID x 1/8" OD | ||
RHEODYNE STAINLES STEEL LOOPS FOR 3725-038 , 3725I-038 INJECTORS | ||||
Volume | Tubing | |||
3065-018 | 2.0 mL Sample Loop | 2.0 mm (0.080”) ID x 1/8" OD | ||
3065-019 | 5.0 mL Sample Loop | 2.0 mm (0.080”) ID x 1/8" OD | ||
3065-023 | 10 mL Sample Loop | 2.0 mm (0.080”) ID x 1/8" OD | ||
3065-025 | 20 mL Sample Loop | 2.0 mm (0.080”) ID x 1/8" OD | ||
RHEODYNE STAINLESS STEEL LOOPS FOR 7725, 7725i, PR/EV700-100, PR/EV703-100, MX MODULE INJECTORS (DO NOT USE FOR 7125) | ||||
Volume | Tubing | |||
7755-020 | 5 µL Sample Loop | 0.18 mm (0.007”) ID x 1/16” OD | ||
7755-021 | 10 µL Sample Loop | 0.30 mm (0.012”) ID x 1/16” OD | ||
7755-022 | 20 µL Sample Loop | 0.30 mm (0.012”) ID x 1/16” OD | ||
7755-023 | 50 µL Sample Loop | 0.51 mm (0.020”) ID x 1/16” OD | ||
7755-024 | 100 µL Sample Loop | 0.51 mm (0.020”) ID x 1/16” OD | ||
7755-025 | 200 µL Sample Loop | 0.76 mm (0.030”) ID x 1/16” OD | ||
7755-026 | 500 µL Sample Loop | 0.76 mm (0.030”) ID x 1/16” OD | ||
7755-027 | 1.0 mL Sample Loop | 0.76 mm (0.030”) ID x 1/16” OD | ||
7755-028 | 2.0 mL Sample Loop | 1.0 mm (0.040”) ID x 1/16” OD | ||
7755-029 | 5.0 mL Sample Loop | 1.0 mm (0.040”) ID x 1/16” OD | ||
1876 | 10 mL Sample Loop | 2.0 mm (0.080”) ID x 1/8” OD | ||
1877 | 20 mL Sample Loop | 2.0 mm (0.080”) ID x 1/8” OD | ||
RHEODYNE STAINLESS STEEL LOOPS FOR 8125 INJESTOR (USE 7755-024 TO 7755-029 FOR VOLUMES > 50 µL) | ||||
Volume | Tubing | |||
8020 | 5 µL Sample Loop | 0.20 mm (0.008”) ID x 1/16” OD | ||
8021 | 10 µL Sample Loop | 0.20 mm (0.008”) ID x 1/16” OD | ||
8022 | 20 µL Sample Loop | 0.25 mm (0.010”) ID x 0.020” OD | ||
8023 | 50 µL Sample Loop | 0.30 mm (0.012”) ID x 1/16” OD |