Contact Us

Honest Industrial Co., Ltd.

Address: Room 604-606, Lucida Industrial Building, 43-47 Wang Lung Street, Tsuen Wan, Hong Kong
Tel: (852)-24068983
Fax: (852)-24061022
Email: sales@materialsupplieshk.com
Rheodyne Stainless Steel Sample Loop, 7755-300
Short Description
Model No.: 7755-300
Brand.: Rheodyne
Clicks: 1159
China Rheodyne Stainless Steel Sample Loop Supplier Honest provides 7755-300 Stainless Steel Sample Loops, tolerance of the metal tubing bore.
Keywords: Sample Loop,

Rheodyne Stainless Steel Sample Loop, 7755-300 Key Specifications / Features

These high quality stainless steel sample loops have burr-free, square-cut ends to ensure a flush connection to valve ports. The size designations of loops are nominal. The actual volumes can differ from the theoretical designations because of the 0.001” (+-0.025 mm) tolerance of the metal tubing bore.
RHEODYNE STAINLESS STEEL LOOPS FOR MXT715-000
        Volume Tubing
7755-300 5 µL Sample Loop 0.18 mm (0.007”) ID x 1/16” OD
7755-301 10 µL Sample Loop 0.30 mm (0.012”) ID x 1/16” OD
7755-302 20 µL Sample Loop 0.30 mm (0.012”) ID x 1/16” OD
7755-303 50 µL Sample Loop 0.51 mm (0.021”) ID x 1/16” OD
7755-304 100 µL Sample Loop 0.51 mm (0.021”) ID x 1/16” OD
RHEODYNE STAINLESS STEEL LOOPS FOR 7125,7010 INJECTORS
(DO NOT USE FOR 7725)
        Volume Tubing
7020 5 µL Sample Loop 0.18 mm (0.007”) ID x 1/16" OD
7021 10 µL Sample Loop 0.30 mm (0.012”) ID x 1/16" OD
7022 20 µL Sample Loop 0.51 mm (0.020”) ID x 1/16" OD
7023 50 µL Sample Loop 0.51 mm (0.020”) ID x 1/16" OD
7024 100 µL Sample Loop 0.51 mm (0.020”) ID x 1/16" OD
7025 200 µL Sample Loop 0.76 mm (0.030”) ID x 1/16" OD
7026 500 µL Sample Loop 0.76 mm (0.030”) ID x 1/16" OD
7027 1.0 mL Sample Loop 0.76 mm (0.030”) ID x 1/16" OD
7028 2.0 mL Sample Loop 1.0 mm (0.010”) ID x 1/16" OD
7029 5.0 mL Sample Loop 1.0 mm (0.040”) ID x 1/16" OD
1876 10 mL Sample Loop 2.0 mm (0.080”) ID x 1/8" OD
1877 20 mL Sample Loop 2.0 mm (0.080”) ID x 1/8" OD
RHEODYNE STAINLES STEEL LOOPS FOR 3725-038 ,           3725I-038 INJECTORS
  Volume Tubing
3065-018 2.0 mL Sample Loop 2.0 mm (0.080”) ID x 1/8" OD
3065-019 5.0 mL Sample Loop 2.0 mm (0.080”) ID x 1/8" OD
3065-023 10 mL Sample Loop 2.0 mm (0.080”) ID x 1/8" OD
3065-025 20 mL Sample Loop 2.0 mm (0.080”) ID x 1/8" OD
RHEODYNE STAINLESS STEEL LOOPS FOR 7725, 7725i, PR/EV700-100, PR/EV703-100, MX MODULE INJECTORS (DO NOT USE FOR 7125)
  Volume Tubing
7755-020 5 µL Sample Loop 0.18 mm (0.007”) ID x 1/16” OD
7755-021 10 µL Sample Loop 0.30 mm (0.012”) ID x 1/16” OD
7755-022 20 µL Sample Loop 0.30 mm (0.012”) ID x 1/16” OD
7755-023 50 µL Sample Loop 0.51 mm (0.020”) ID x 1/16” OD
7755-024 100 µL Sample Loop 0.51 mm (0.020”) ID x 1/16” OD
7755-025 200 µL Sample Loop 0.76 mm (0.030”) ID x 1/16” OD
7755-026 500 µL Sample Loop 0.76 mm (0.030”) ID x 1/16” OD
7755-027 1.0 mL Sample Loop 0.76 mm (0.030”) ID x 1/16” OD
7755-028 2.0 mL Sample Loop 1.0 mm (0.040”) ID x 1/16” OD
7755-029 5.0 mL Sample Loop 1.0 mm (0.040”) ID x 1/16” OD
1876 10 mL Sample Loop 2.0 mm (0.080”) ID x 1/8” OD
1877 20 mL Sample Loop 2.0 mm (0.080”) ID x 1/8” OD
RHEODYNE STAINLESS STEEL LOOPS FOR 8125 INJESTOR           (USE 7755-024 TO 7755-029 FOR VOLUMES > 50 µL)
  Volume Tubing
8020 5 µL Sample Loop 0.20 mm (0.008”) ID x 1/16” OD
8021 10 µL Sample Loop 0.20 mm (0.008”) ID x 1/16” OD
8022 20 µL Sample Loop 0.25 mm (0.010”) ID x 0.020” OD
8023 50 µL Sample Loop 0.30 mm (0.012”) ID x 1/16” OD
 

Products Related to Rheodyne Stainless Steel Sample Loop, 7755-300