Short Description
China Switch Franchiser Honest provides Limit Switches made by Schmersal, Position, Medium Heavy Position, UK432Y-M20, EN 60947-5-1, Universal range.
Keywords: Limit Switch, Position Switch,
Position switch / medium heavy Position switch / Universal range U - Metal enclosure / U 432 / U 432 Offset roller lever K |
|
|
|
• Metal enclosure • 2 Contacts • 62 mm x 80 mm x 50 mm (basic component) • Switching points and contact function adjustable • 3 cable entries M 20 x 1.5 • Actuator heads can be repositioned by 4 x 90° |
|
Ordering details
|
|
Product type description | UK 432Y |
Article number | 101166388 |
EAN code | 4030661214597 |
Standards | EN 60947-5-1 |
Compliance with the Directives (Y/N) | Yes |
Suitable for safety functions (Y/N) | No |
Standard housing (Y/N) | No |
Materials | |
- Material of the housings | light alloy die-casting |
- Roller material | Plastic |
- Material of the contacts | Silver |
Housing coating | painted |
Weight | 340 g |
Slide form | Castor |
Mechanical data
|
|
Design of electrical connection | Screw connection |
Cable section | |
- Min. Cable section | 1.5 mm² |
- Max. Cable section | 2.5 mm² |
AWG-Number | 13 |
Active principle | mechanical |
Mechanical life | 10.000.000 operations |
Contact life | 2.000.000 operations, at 6 A / 400 V, cos φ = 0,4 |
Design of actuating element | Offset roller lever |
Contact opening | 2 x 1.5 mm |
Actuating speed with vertical actuating angle to switch axis | |
- Min. Actuating speed | 1 mm/min |
- Max. Actuating speed | 0,5 m/s |
- Actuating angle from left of switch axis | 45° |
- Actuating angle from right of switch axis | 30° |
notice | All indications about the cable section are including the conductor ferrules. |
Ambient conditions
|
|
Ambient temperature | |
- Min. environmental temperature | −20 °C |
- Max. environmental temperature | +60 °C |
Protection class | IP65 to IEC/EN 60529 |
Electrical data
|
|
Design of control element | Opener (NC) |
Switching principle | Creep circuit element |
Number of shutters | 0 piece |
Number of openers | 2 piece |
Rated insulation voltage Ui | 500 V |
Thermal test current Ithe | 16 A |
Max. fuse rating | 16 A gG D-fuse |
Dimensions
|
|
Dimensions of the sensor | |
- Width of sensor | 62 mm |
- Height of sensor | 118 mm |
- Length of sensor | 50 mm |
Roller wide | 8.5 mm |
Roller diameter | 20 mm |
notice
|
|
Type of contact and switching points can be factory set to order. | |
notice | Actuation from the right should be avoided, since this reduces the mechanical life of the position switch. |
Indication legend
|
|
see drawing: Operating principle | |
Contact function, i. e. NC or NO contact, and switching points can be adjusted using a screwdriver | |
Diagram
|
|
Note Diagram positive break NC contact active no active Normally-open contact Normally-closed contact |
|
Switch travel diagram
|
|
Notes Switch travel diagram Contact closed Contact open Setting range Break point Positive opening sequence/- angle VS adjustable range of NO contact VÖ adjustable range of NC contact N after travel |