Short Description
China Shako Inverter Supplier Honest provides TDS-V8-L Inverters, 220V, 3 Phase, Sine PWM, 0.1Hz~400Hz, used as LED Operator or LCD Operator.
Keywords: Sine PWM Inverter, Inverter,
Input Voltage Class | 220V 3 Phase | ||||||||||||||||
Model | TDS-V8-L | ||||||||||||||||
0P7 | 1P5 | 2P2 | 3P7 | 5P5 | 7P5 | 011 | 015 | 018 | 022 | 030 | 037 | 045 | 055 | 075 | |||
Max. Applicable Motor | HP | 1 | 2 | 3 | 5 | 7.5 | 10 | 15 | 20 | 25 | 30 | 40 | 50 | 60 | 75 | 100 | |
Motor Output(CT)* | kW | ||||||||||||||||
0.75 | 1.5 | 2.2 | 3.7 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 | 55 | 75 | |||
Weight (kg) | 2 | 2 | 2.4 | 2.4 | 5.5 | 5.5 | 13.1 | 13.1 | 24.5 | 24.5 | 24.5 | 46 | 46 | ||||
Power Output | Rated Output Capacity(kVA) | 2 | 3 | 4 | 7.5 | 10.1 | 13.7 | 20.6 | 27.4 | 34 | 41 | 54 | 68 | 78 | |||
Rated Output Current(A) | 4.8 | 7.1 | 9.6 | 17.5 | 24 | 32 | 48 | 64 | 80 | 96 | 130 | 160 | 183 | ||||
Max. Output Voltage | 3 phase 200~230V | ||||||||||||||||
Max. Output Frequency(Hz) | Through parameter setting ( 0 Hz to 400Hz) | ||||||||||||||||
Power Source | Rated Voltage, Frequency | 3 Phase 200V~230V,50/60Hz | |||||||||||||||
Allowable Voltage Fluctuation | -15% ~ +10% | ||||||||||||||||
Allowable Frequency Fluctuation | ±5% |
Control Characteristics | Operation Mode | LED Operator or LCD Operator |
Control Mode | Sine PWM | |
Frequency Control Range | 0.1Hz~400Hz | |
Frequency Accuracy(varied with temperature) | Digital Command:±0.01%(-10 ~ +40℃), Analog Command:±0.1% (25℃ ±10℃) |
|
Frequency Command Resolution | Digital Command:0.01Hz, Analog Command:0.06Hz/60Hz |
|
Frequency Output Resolution | 0.01Hz | |
Overload Resistibility | 150% Rated Current for 1 Minute(CT) ; 120%Rated Current for 1Minute(VT) | |
Frequency Setting Signal | DC 0 ~ +10V / 4 ~ 20mA | |
Acc./Dec. Time | 0.0~6000.0 sec (Accel/Decel Time Can be Set Independent) | |
Voltage-Frequency Characteristics | V/F Curve Can be Set Through Paramenter Setting(16Types) | |
Regeneration Torque | 100%,2%ED,5 sec | |
Main Control Function | Auto Torque Boost, Slip Compensation, Restart After Momentary Power Loss, Energy-Saving, PID Control, RS-485 Communication, Simple PLC Function, Sensorless Vector Control | |
Extra Function | Up/Down Operation, 4 Different Sets of Fault Status Record (Including Latest One), Cumulative Power On & Operation Hour Memory, Energy Savings Function, MODBUS Communication, Multiple-Pulse Output Ports, etc. | |
Protection Function | Stall Prevention | During Acceleration/Deceleration and Constant Speed Operation (Current Level can be Selected During Acceleration and Constant Speed Operation. During Deceleration, Stall Prevention can be Enabled or Disabled) |
Instantaneous Overcurrent (OC) | Stopped if above 200% Rated Current | |
Inverter overloads Protection(OL2) | Stopped if above 150% Rated Current for 1 Minute | |
Motor Overload (OL1) | Electronic Overload Curve Protection | |
Over voltage(OV) | Motor Coasts to Stop if VDC > 410V (230V) or VDC > 820V (460V) | |
Low voltage(UV) | Motor Coasts to Stop if VDC < 200V (230V) or VDC < 400V (460V) | |
Momentary Power Loss Ride-Through time | Motor Coasts to Stop after Momentary Power Loss Lasting > 15ms | |
Overheat (OH) | Protection by Thermistor | |
Grounding Protection (GF) | Protection by the DC Current Sensor | |
Charge Indication | Light when the DC Bus Voltage ≧50V | |
Mechanical Construction | Enclosed, Wall-Mounted Type (NEMA-1) | |
Cooling | Forced | |
Weight(Kg) | ||
Environmental Conditions | Location | Indoor (No Corrosive Gas and Dust Present) |
Ambient Temperature | +14 to 104oF, -10 to +40ºC (Not Frozen) | |
Storage Temperature | -4 to 140oF, -20 to +60ºC | |
Humidity | Below 90%RH (Non-Condensing) | |
Altitude, Vibration | Below 3300ft (1000m), 5.9m/S两 (0.6G), (JISC0911 Standard) | |
Communication Function | RS-485 Built-in (MODBUS ) | |
EMI | Meet EN50081-2 (1994) With Specified EMI Filter | |
EMC Compatibility | Meet Pr EN50082-2 |